Verification brief · Rev 1.0 ·
NeuraEdge keyword-spotting verification
A pre-silicon functional check of one fixed keyword-spotting model on the NeuraEdge reference system.
Download the one-page brief (PDF)- Matching inferences
- 72/72
- Distinct selected inputs
- 17
- Execution environment
- RTL simulation
Setup and result
Selected audio samples were converted into features before simulation. The test replayed those inputs through a fixed model in a single NeuraEdge reference configuration. Runs covered ready and stalled memory conditions and two memory placements.
Every valid inference matched the expected final outputs from the integer reference. Intermediate results and ordered memory activity also matched the expected traces. Repeated runs over the selected inputs account for the difference between the number of inputs and the number of inferences.
One replay, byte for byte
First valid inference in a two-input replay. Audio-derived features were supplied to the RTL simulation. The simulated SRAM used the lower test placement with no injected stalls.
- Integer reference
7D 80 80 80 80 81 80 80 80 80 80 81- Observed in RTL
7D 80 80 80 80 81 80 80 80 80 80 81
All 12 output bytes match.
What the result covers
The result is a functional comparison for this workload and configuration. Silicon operation, power, target clock rates, live audio capture and buyer integration remain outside the test scope. The replay does not measure keyword-recognition accuracy on a held-out dataset.
Evaluate your configuration
Bring your model format, host and memory requirements, and acceptance criteria. We’ll agree what evidence can be reviewed and what needs a separate test.
Request a technical evaluation